پرتو طب نگار گویا | پرتو طب | پرتوطب | PartoTeb | Parto Teb | Ortho Clinical Diagnostics
پرتو طب نگار گویا | پرتو طب | پرتوطب | PartoTeb | Parto Teb | Ortho Clinical Diagnostics

ORTHO WORKSTATION – Immunohematology

System Dimensions

Width: 575 mm /22.64 inche
Depth: 325 mm /12.80 inches
Hight: 220 mm /8.66 inches
Weight: 10.89 kg /24 pounds

Share

Introducing the new ORTHO™ Workstation. The only integrated 2 in 1 compact system with reliable Ortho BioVue® Column Agglutination Technology, for blood banking with confidence.

Precision & Accuracy
• Uses proven reliable BioVue® Cassettes
– Clear, stable, well-defined end points
– Objective interpretation of results
– Full assay portfolio
– Ability to use reduced sample volume
• Five minute centrifuge cycle time
• Validated system of BioVue® Cassette with centrifuge & incubator

Convenient, compact 2 in 1 ORTHO™ Workstation
• Integrated system of BioVue® CAT cassettes, centrifuge and incubator
• Light weight - just under 11kg
• Small footprint for space-constrained labs
• Labs can standardize on one technology

Ease of Use
• Language-neutral icons
• Enhanced alarm systems*
• Improved cassette incubator design for rapid loading & unloading of BioVue® Cassettes*
• Easy to perform centrifuge QC using a tachometer
• Quick access to holding area for centrifuge balance-cassette

Improved Process Controls
• Incubator temperature monitoring with visual indicator
• Unique beeping pattern to indicate cycle completion
• Enhanced error code intelligence for troubleshooting
• Quiet centrifuge with translucent panels for visual monitoring

Designed with the environment in mind
• Reduction in device weight by 47% *
• Reduction in external packaging by 53%*
• Reduction in Reference Guide size by 95%*
• Packaged in an innovative, re-usable multi-purpose lab bag

Dimensions:
Height – 220 mm (8.66 inches)
Width – 575 mm (22.64 inches)
Depth – 325 mm (12.80 inches)

Weight: 10.89 kg (24 lb)

Power Requirements: 100 – 240 V~, 50/60 Hz, single phase (Input auto-senses voltage/current, no manual selection required)

Power Consumption: 150 VA

Fuses: 2 required, T4AH250V - 4 Amp, 250V, ceramic, time delay, 5x20 mm

Cycle Speed: Phase 1: 793 rpm ± 10 rpm Phase 2: 1509 rpm ± 10 rpm

Speed Indicator: 4 digits

Timing Indicator: 4 digits

Cycle Timing: 5 minutes ± 10 sec. (including ramp-up time)
Centrifuge Cassette Capacity: 10 cassettes
Incubation Temperature: 37°C ± 2°C
Incubator Cassette Capacity: 20 cassettes (two sections of 10)

Noise Level Generated: Maximum 50 dba at 1 meter (during normal operation)

Expected Life: 10 years

Description

Introducing the new ORTHO™ Workstation. The only integrated 2 in 1 compact system with reliable Ortho BioVue® Column Agglutination Technology, for blood banking with confidence.